|
Usuarios conectados
Actualmente hay 5790 visitantes online.
|
Productos
|
Información
|
Destacado
|
|
|
|
|
No hay comentarios de productos.
Vs Vs ADJ
VR8102
(1) Select WHITE PATTERN of HEAT RUN mode by pressing ADJ button on Remote Control for adjustment then operate HEAT RUN more than 15 minute. (2) Supply 10 step gray scale bar signal in pattern generater. (A/V Input) (3) To adjust Low Light, stick sensor to 9th pattern(Dark), select the W/B by pressing ADJ button on Remote Control for adjustment and press the VOL + button enter Adjustment Mode. After select the G cut and B cut, press the VOL +/- Key and adjust it until color coordination becomes (R cut fixation) color coordination : X=0.270±0.003, Y=0.280±0.003 color temperature : 10,000cK ± 500cK (4) To adjust High Light, stick sensor to 2th pattern(White), select the W/B by pressing ADJ button on Remote Control for adjustment and press the VOL + button enter Adjustment Mode. After select the R GAIN and G GAIN, press the VOL +/Key and adjust it until color coordination becomes (B GAIN fixation) color coordination : X=0.270±0.003, Y=0.280±0.003 color temperature : 10,000cK ± 500cK (5) Confirm the result of the High Light adjustment. If the deviation of High Light occur, operate the adjustment of Low Light and High Light again. (6) Exit adjustment mode using Enter button.
- Vy Vsetup - Vy ADJ
VR8103
Vsetup ADJ
VR8104
Va
Va ADJ
VR8105
<Fig 2> Connection Diagram of POWERWEL Power Adj. for Measuring
4. Adjustment of White Balance
4-1. Required Equipment
Color analyzer(CA-100 or same production)
4-2. Connection Diagram of Equipment for Measuring
COLOR ANALYZER TYPE; CA-100 High Light 85±5cd/m2 Low Light 8±3cd/m2
CVBS Signal Input PDP MONITOR Window Pattern MSPG-2100 or MSTG-5200
<Fig 3> Connection Diagram of Automatic Adjustment [ After stop the Micom by pressing IN-START Key on Remote Control, insert the P1002 with automatic adjustment of connector. After remove connector, move the Micom by pressing ENTER Key.
4-3. Adjustment of White Balance
� White Balance should be done after RGB cut-off become adjustment. � Operate the Zero-calibration of the CA�100, then stick sensor to PDP module surface when you adjust.
- 10 -
|
|
|
> |
|